7.1.1 Plug/Jack Location List
How to Use the Plug/Jack Location List
To find which position to install specific connectors to, refer to the table 'Plug/Jack Location List ' for
Figure No. and Item No., and then to the figure in 'Plug/Jack Positions.'
P/J No. on 'Plug/Jack Location List' is expressed in the four ways below:
J250 represents Jack 250.
P250 represents Plug 250.
CN1 represents Connector 1.
FS1 represents Faston Terminal 1.
Version 1.1
DC SC2020
Figure 1 7001
Plug/Jack Location List
Table 1 Plug/Jack Location List
P/J
Fig
Item
P/J1
9
21
P/J1
3
13
P1
10
6
J1
11
17
J1
8
15
P2
3
10
P2
10
5
J2
11
15
P3
3
9
P/J3
3
11
P3/J3C
8
5
J3
11
13
J4
11
12
P5
3
8
P5/J5C
8
6
J5
11
19
P/J6
8
4
J6
11
18
J7
11
16
P/J9
8
13
P/J10
8
11
P/J11
8
10
P/J12
8
9
P/J13
8
16
P14
8
3
P/J15
8
2
P/J19
8
1
P40
8
17
P/J100
4
8
P/J101
4
4
P/J101
12
1
P/J102
4
3
P/J103
4
2
P/J104
4
1
P/J104
12
5
P/J105
5
1
P/J106
5
1
P/J106
12
8
05/2014
7-3
Remarkes (where to Connect)
Drive PWB
UI PWB C
LVPS (Connect to J510)
AC Inlet
ESS PWB
UI PWB C
LVPS (Connect to J511)
AC Inlet
UI PWB L
UI PWB C
ESS PWB
Main Power Switch
Main Power Switch
UI PWB C (Connect to J840)
ESS PWB
Main Power Switch
ESS PWB
Main Power Switch
AC Inlet
ESS PWB
ESS PWB
ESS PWB
ESS PWB
ESS PWB
ESS PWB (Connect to J421(DADF))
ESS PWB
ESS PWB
ESS PWB (Debug)
Waste Toner Bottle Full Sensor
Toner CRUM Connector Assembly (Y)
Tary 2 Paper Size Sensor
Toner CRUM Connector Assembly (M)
Toner CRUM Connector Assembly (C)
Toner CRUM Connector Assembly (K)
STM Left Cover Switch
Xero CRUM Connector Assembly (Y)
Xero CRUM Connector Assembly (M)
Tray 2 No Paper Sensor