3.2.3 Fusing Unit Paper wrinkle Alignment adjustment
[Procedure]
1.
Installation/removal of Adjustment Bracket
(1) Remove the Fusing Unit.
Figure 1 j0lbs34001
(2) Remove the alignment adjustment bracket on the Front Side.
•
Remove the Screw (2).
Figure 2 j0lbs34002
•
N: Nominal position
•
M: Minus position
•
P: Plus position
Version 1.1
DC SC2020
2.
Adjustment Method
Refer to "Alignment Adjustment Bracket Used Flow" in Step3 for adjustment.
(1) Move the adjustment bracket to N -> M when the paper wrinkle appears on the left side.
i.
Temporary tack the Screw in the left M hole.
ii.
Fasten the Screw in the right M hole.
iii.
Tighten the left M Screw.
05/2014
3.2.2 How to use the image quality troubleshooting (IPS)
3-27
Figure 3 j0lbs34009
Figure 4 j0lbs34010