5.
Check that the current value column becomes '0'.
6.
If the problem persists after performing the above procedure, check the following:
Out of Lamp (CIS Sensor Assy) (IIT Output[062-002]).
Disconnection, shortage or contact failure of wire between CIS Sensor Assy
PWB
J15
(Especially check to see that the Flat Cable is not inserted in an angle).
7.
If no problem is found, replace the ESS PWB.
062-396 CCD Cable Connection Fail
BSD-ON:CH6.3
A CCD Flat Cable connection error was detected.
Cause/Action
1.
Turn the power OFF and ON.
2.
Turn the Power Off and check to see if there is disconnection, shortage or contact failure of wire
between CIS Sensor Assy
J700
and ESS PWB
not inserted at an angle).
3.
If no problem is found, replace the following parts in sequence:
Flexible Flat Cable (CIS Cable)
(PL
ESS PWB
(PL
18.2)
062-790 Copy Limit (Scan-JobAbort)
BSD-ON:-
Detected the limit of copy.
Cause/Action
1.
Delete the Job in suspended state. Press the [Close] button or recover after the time course which
was set in Fault Timeout.
2.
Check the document and rerun the Job.
062-956 Not-Supported Doc Size Platen
BSD-ON:-
Detected unsupported document size in Platen Scan.
Cause/Action
1.
Delete the Job in suspended state. Press the [Close] button or recover after the time course which
was set in Fault Timeout.
2.
Check the document and rerun the Job.