Fuji Xerox DocuCentre SC2020 Service Manual page 607

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

6.4.8.1 Digital Input
Digital Input checks whether the digital input (DI) components function properly.
The display shows [0] when the digital input test is started, and the value will be increased when the DI
components are switched from OFF to ON, which is used for confirming that the component functions
normally.The test targets all DI components.
Table 1 Digital Input Parameter
Chain
Link
Parameter
042
200
YMC Link Sensor
071
101
#1 No Paper Sensor
071
104
#1 TRAY Paper Size Sensor Digital
072
101
#2 No Paper Sensor
072
102
#2 Level Sensor
072
103
#2 Feed Out Sensor
072
104
#2 TRAY Paper Size SensorDigital
075
100
MSI No Paper Sensor Tray1
077
101
#1 Exit Sensor
077
104
Regi Sensor
077
121
TM Regi Stop Signal input
077
300
Left Hand Interlock Switch
077
303
Front Interlock Switch
077
306
TM Left Hand Interlock Switch
091
200
Waste Toner Full Sensor
Digital Input Test Example
This section explains Digital Input Text using [077-303: Front Interlock Switch] as an example.
1.
Enter the CE mode. (See
"6.4.2
How To Enter the CE Mode".)
2.
Confirm that the [Printer Diag] is selected, and then press the [OK] button.
3.
Use the [Down arrow] button to select [IOT Diag], and press the [OK] button.
Version 1.1
DC SC2020
4.
Press the [OK] button.
5.
Use the [Down arrow] or [Up arrow] button to select [077-303], and press the [OK] button.
05/2014
6-209
Figure 1 j0bs64010
Figure 2 j0bs64011
Figure 3 j0bs64012
6.4.8.1 Digital Input
General

Advertisement

Table of Contents
loading