0Ch) Fusing Unit Cold Not Ready Return Time Fail; Fusing Unit Near End Warning; Fusing Unit Life Warning; Chain 10 - Fuji Xerox DocuCentre SC2020 Service Manual

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

DC SC2020
Version 1.1
BSD-ON:CH10.3
Fusing Unit NC Sensor compensation output AD value was detected below 130 for more than 10
consecutive times.
Fusing Unit NC Sensor detection output AD value was detected below 150 for more than 10 consec-
utive times.
NOTE: . When turning the power OFF, turn OFF the Power Switch first and then the Main Power Switch.
Cause/Action
1.
Turn the power OFF and ON.
2.
Turn OFF the power and check the following:
The Fusing Unit for improper installation
The Drawer Connector between the Fusing Unit and the Main Unit (DP/DJ600S) for broken/
bent pins, foreign substances, burns, and etc.
Disconnection, shortage or contact failure of wire between Fusing Unit
PWB P414.
3.
If no problem is found, replace the following parts in sequence:
Fusing Unit
(PL
7.1)
DRIVE PWB
(PL
18.2)
ESS PWB
(PL
18.2)
4.
After replacing the Fusing Unit, enter CE Mode, go to Printer Diag > Parameter > Life > Fusing Unit
Print Count / Fusing Unit Time Count and initialize the Life Counters.

010-397 (0Ch) Fusing Unit Cold Not Ready Return Time Fail

BSD-ON:CH10.3,CH10.2
The recovery time from Low Temperature Not Ready state exceeded the specified time.
Cause/Action
1.
Turn the power OFF and ON.
2.
Turn OFF the power and check the following:
The Fusing Unit for improper installation
The Drawer Connector between the Fusing Unit and the Main Unit (DP/DJ600) for broken/bent
pins, foreign substances, burns, and etc.
Disconnection, shortage or contact failure of wire between Fusing Unit
Disconnection, shortage or contact failure of wire between Fusing Unit
PWB J414.
3.
If no problem is found, replace the following parts in sequence:
Fusing Unit
(PL
7.1)
LVPS
(PL
18.3)
DRIVE PWB
(PL
18.2)
05/2014
2-24
ESS PWB
4.
After replacing the Fusing Unit, enter CE Mode, go to Printer Diag > Parameter > Life > Fusing Unit
Print Count / Fusing Unit Time Count and initialize the Life Counters.

010-420 Fusing Unit Near End Warning

BSD-ON:CH10.3
Detected that the Fusing Unit replacement time is approaching.
Cause/Action
Prepare new Fusing Unit as necessary.

010-421 Fusing Unit Life Warning

DJ600S
and DRIVE
BSD-ON:CH10.3
Detected the replacement time of the Fusing Unit.
Cause/Action
Replace the Fusing Unit.
After replacing, enter CE Mode, go to Printer Diag > Parameter > Life > Fusing Unit Print Count /Fusing
Unit Time Count and initialize the Life Counters.
DJ600
and LVPS P2.
DJ600S
and DRIVE
(PL
18.2)
(PL
7.1)
(PL
7.1)