Fusing Unit NC Sensor compensation output AD value was detected below 130 for more than 10
consecutive times.
•
Fusing Unit NC Sensor detection output AD value was detected below 150 for more than 10 consec-
utive times.
NOTE: . When turning the power OFF, turn OFF the Power Switch first and then the Main Power Switch.
Cause/Action
1.
Turn the power OFF and ON.
2.
Turn OFF the power and check the following:
•
The Fusing Unit for improper installation
•
The Drawer Connector between the Fusing Unit and the Main Unit (DP/DJ600S) for broken/
bent pins, foreign substances, burns, and etc.
•
Disconnection, shortage or contact failure of wire between Fusing Unit
PWB P414.
3.
If no problem is found, replace the following parts in sequence:
•
Fusing Unit
(PL
7.1)
•
DRIVE PWB
(PL
18.2)
•
ESS PWB
(PL
18.2)
4.
After replacing the Fusing Unit, enter CE Mode, go to Printer Diag > Parameter > Life > Fusing Unit
Print Count / Fusing Unit Time Count and initialize the Life Counters.
010-397 (0Ch) Fusing Unit Cold Not Ready Return Time Fail
BSD-ON:CH10.3,CH10.2
The recovery time from Low Temperature Not Ready state exceeded the specified time.
Cause/Action
1.
Turn the power OFF and ON.
2.
Turn OFF the power and check the following:
•
The Fusing Unit for improper installation
•
The Drawer Connector between the Fusing Unit and the Main Unit (DP/DJ600) for broken/bent
pins, foreign substances, burns, and etc.
•
Disconnection, shortage or contact failure of wire between Fusing Unit
•
Disconnection, shortage or contact failure of wire between Fusing Unit
PWB J414.
3.
If no problem is found, replace the following parts in sequence:
•
Fusing Unit
(PL
7.1)
•
LVPS
(PL
18.3)
•
DRIVE PWB
(PL
18.2)
05/2014
2-24
•
ESS PWB
4.
After replacing the Fusing Unit, enter CE Mode, go to Printer Diag > Parameter > Life > Fusing Unit
Print Count / Fusing Unit Time Count and initialize the Life Counters.
010-420 Fusing Unit Near End Warning
BSD-ON:CH10.3
Detected that the Fusing Unit replacement time is approaching.
Cause/Action
Prepare new Fusing Unit as necessary.
010-421 Fusing Unit Life Warning
DJ600S
and DRIVE
BSD-ON:CH10.3
Detected the replacement time of the Fusing Unit.
Cause/Action
Replace the Fusing Unit.
After replacing, enter CE Mode, go to Printer Diag > Parameter > Life > Fusing Unit Print Count /Fusing
Unit Time Count and initialize the Life Counters.