Chain-Link NVM Name
751-238
#63mm/s No. of Prints
751-239
#126mm/s No. of Prints
751-240
B4S-G No. of Prints
751-241
11X17-G No. of Prints
751-242
11X19-G No. of Prints
751-243
BW No. of Prints
751-244
4Color No. of Prints
751-245
Blank No. of Prints
751-246
Xero Initial Band SW
751-247
Xero Initial Band Threshold Value
751-248
#Y Xero Initial Band Cin
751-249
#M Xero Initial Band Cin
751-250
#C Xero Initial Band Cin
751-251
#K Xero Initial Band Cin
751-252
#Y Xero Initial Band Length
Version 1.1
DC SC2020
Table 1 NVM 751_Xero/Clean 2 List
Default
Minimum
Maximum
Value
value
value
Description
0
0
4294967295 No. of Prints by Process Speed Category for Waste Toner Container (#PS)
Maintain the M/C counter value right after replacing waste container, calcu-
late the difference with M/C counter when acquiring diagnosis data and
make it as Diagnosis Data.
0
0
4294967295 No. of Prints by Process Speed Category for Waste Toner Container (#PS)
Maintain the M/C counter value right after replacing waste container, calcu-
late the difference with M/C counter when acquiring diagnosis data and
make it as Diagnosis Data.
0
0
4294967295 No. of Prints by Size Category for Waste Toner Container (B4S-G)
Maintain the M/C counter value right after replacing waste container, calcu-
late the difference with M/C counter when acquiring diagnosis data and
make it as Diagnosis Data.
0
0
4294967295 No. of Prints by Size Category for Waste Toner Container (11X17-G)
Maintain the M/C counter value right after replacing waste container, calcu-
late the difference with M/C counter when acquiring diagnosis data and
make it as Diagnosis Data.
0
0
4294967295 No. of Prints by Size Category for Waste Toner Container (11X19-G)
Maintain the M/C counter value right after replacing waste container, calcu-
late the difference with M/C counter when acquiring diagnosis data and
make it as Diagnosis Data.
0
0
4294967295 No. of Prints by Color Category for Waste Toner Container (BW)
Maintain the M/C counter value right after replacing waste container, calcu-
late the difference with M/C counter when acquiring diagnosis data and
make it as Diagnosis Data.
0
0
4294967295 No. of Prints by Color Category for Waste Toner Container (4Color)
Maintain the M/C counter value right after replacing waste container, calcu-
late the difference with M/C counter when acquiring diagnosis data and
make it as Diagnosis Data.
0
0
4294967295 No. of Prints by Color Category for Waste Toner Container (Blank)
Maintain the M/C counter value right after replacing waste container, calcu-
late the difference with M/C counter when acquiring diagnosis data and
make it as Diagnosis Data.
1
0
2
0: Do not perform, 1: Perform, 2: Force Perform
1000
0
1000
Xero Initial Band Cycle Threshold Value
100
0
100
Xero Initial Band Cin 0 = 0%, 100 = 100%, Setting is in the increment of 10%
(round down 0~9)
100
0
100
Xero Initial Band Cin 0 = 0%, 100 = 100%, Setting is in the increment of 10%
(round down 0~9)
100
0
100
Xero Initial Band Cin 0 = 0%, 100 = 100%, Setting is in the increment of 10%
(round down 0~9)
100
0
100
Xero Initial Band Cin 0 = 0%, 100 = 100%, Setting is in the increment of 10%
(round down 0~9)
50
0
300
Xero Initial Band Length
05/2014
6-87
Write
Allowed/
Can be
Unit
Protected
initialized
PV
O
O
PV
O
O
PV
O
O
PV
O
O
PV
O
O
PV
O
O
PV
O
O
PV
O
O
-
O
O
0.1[Cycle]
O
O
%
O
O
%
O
O
%
O
O
%
O
O
mm
O
O