Fuji Xerox DocuCentre SC2020 Service Manual page 312

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

DC SC2020
Version 1.1
Mode: "2 to 1 Sided"
3.
Check that the distance between the Lead Edge and the refer-
ence value in the second copy is 10 +/-1.9 mm.
If it is not within the specified range, adjust to the specified
range using the following procedure. (Figure 2)
Figure 2 j0ku42053
Adjustment
1.
Input the NVM [711-141].
2.
Adjust to the specified range (10 +/-1.9 mm).
If the distance between the Lead Edge and the reference value
is
12.0 mm or higher, increase the NVM value.
8.0 mm or lower, decrease the NVM value.
(NVM1Step=0.1mm)
3.
Repeat the procedure until the value is within the specified
range (10 +/-1.9 mm).
As there will be differences in the Regi according to the ratio,
adjust the following NVM.
Table 2
Basic Scan Speed
NVM
[mm/s]
NVM [711-022]
165.0
NVM [711-024]
82.5
Reduce / Enlarge
100.0%
Other than 100.0%
05/2014
4-110
Disassembly/Assembly and Adjustment
56. DADF