Fuji Xerox DocuCentre SC2020 Service Manual page 544

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

DC SC2020
Version 1.1
Chain-Link NVM Name
753-645
Recovery Adjustment No. Maximum Value_Small Filling
753-646
ADC_Vcln_Patch Size
753-647
ADC Sensor Contamination State Counter
753-648
ADC Sensor Warning Counter_TC Patch[Y]
753-649
ADC Sensor Warning Counter_TC Patch[M]
753-650
ADC Sensor Warning Counter_TC Patch[C]
753-651
ADC Sensor Warning Counter_TC Patch[K]
753-652
Disp Switch SW in Image Profile LIFE
753-653
Delta RADC_Tone_Target Deve Correction Amount
[Y][Patch1]
753-654
Delta RADC_Tone_Target Deve Correction Amount
[Y][Patch2]
753-655
Delta RADC_Tone_Target Deve Correction Amount
[Y][Patch3]
753-656
Delta RADC_Tone_Target Deve Correction Amount
[Y][Patch4]
753-657
Delta RADC_Tone_Target Deve Correction Amount
[M][Patch1]
753-658
Delta RADC_Tone_Target Deve Correction Amount
[M][Patch2]
753-659
Delta RADC_Tone_Target Deve Correction Amount
[M][Patch3]
753-660
Delta RADC_Tone_Target Deve Correction Amount
[M][Patch4]
753-661
Delta RADC_Tone_Target Deve Correction Amount
[C][Patch1]
753-662
Delta RADC_Tone_Target Deve Correction Amount
[C][Patch2]
753-663
Delta RADC_Tone_Target Deve Correction Amount
[C][Patch3]
753-664
Delta RADC_Tone_Target Deve Correction Amount
[C][Patch4]
753-665
Delta RADC_Tone_Target Deve Correction Amount
j[K][Patch1]
753-666
Delta RADC_Tone_Target Deve Correction Amount
[K][Patch2]
753-667
Delta RADC_Tone_Target Deve Correction Amount
[K][Patch3]
753-668
Delta RADC_Tone_Target Deve Correction Amount
[K][Patch4]
05/2014
6-146
Table 1 NVM 753_Process Control 2 List
Default
Minimum
Maximum
Value
value
value
Description
4
0
255
Maximum No. of Retry for Small Filling CTRG Recovery
0
0
1023
ADC_Vcln Output Mean of Patch Size Vclean
0
0
65535
ADC Sensor Contamination State Counter
0
0
65535
ADC Sensor Warning Counter due to TC Patch Fail
0
0
65535
ADC Sensor Warning Counter due to TC Patch Fail
0
0
65535
ADC Sensor Warning Counter due to TC Patch Fail
0
0
65535
ADC Sensor Warning Counter due to TC Patch Fail
0
0
1
Disp Switch SW in Image Profile LIFE
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
0
-1024
1023
Delta RADC_Tone_Deve Correction Amount of Target Value
General
6.3.14 NVM 753_Process Control 2 List
Write
Allowed/
Can be
Unit
Protected
initialized
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O

Advertisement

Table of Contents
loading

Table of Contents