Fuji Xerox DocuCentre SC2020 Service Manual page 473

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

Chain-Link NVM Name
749-268
LPH_YMC_INHIBIT_TRANS_ON
749-269
LPH_WARM_ON
749-270
LPH_WARM_WAIT
749-271
LPH_PG_MODE_Y
749-272
LPH_PG_MODE_M
749-273
LPH_PG_MODE_C
749-274
LPH_PG_MODE_K
749-275
LPH_SMILE_USHAPE_ON
749-276
LPH_CRATIO_THERM_SEL
749-332
LPH_UC_Y
749-333
LPH_UC_M
749-334
LPH_UC_C
749-335
LPH_UC_K
749-336
LPH_OUT_LOCAL_OFFSET_Y
749-337
LPH_OUT_LOCAL_OFFSET_M
749-338
LPH_OUT_LOCAL_OFFSET_C
749-339
LPH_OUT_LOCAL_OFFSET_K
749-428
LPH_HSYNC_BLANK
Version 1.1
DC SC2020
Table 1 NVM 749_LPH List
Default
Minimum
Maximum
Value
value
value
Description
0
0
1
If LPH_YMC_INHIBIT_TRANS_ON (NVM) = 1, to stop the transmission of IBY of YMC
during Single K Print, put INHIBIT_TRANS to 1 (ON).
If LPH_YMC_INHIBIT_TRANS_ON (NVM) = 0, to not stop the transmission of IBY of
YMC during Single K Print, put INHIBIT_TRANS to 0 (OFF).
0: Transmit with YMC, 1: Do not transmit with YMC
0
0
1
0: Do not perform default value, Heat Cycle
1: Perform Heat Cycle
10
0
255
Unit: 100msec, Default Value: 10 (1.0 sec)
1
0
7
PATTERN GENERATER MODE
Select TP1~6 ON/OFF.
1
0
7
PATTERN GENERATER MODE
Select TP1~6 ON/OFF.
1
0
7
PATTERN GENERATER MODE
Select TP1~6 ON/OFF.
1
0
7
PATTERN GENERATER MODE
Select TP1~6 ON/OFF.
6
0
255
Switches the ON/OFF for usage in IOT for Light Amount Correction Function of IBY.
bit0: NotUsed
bit1: Specify whether to conduct USHAPE Correction SW, Ushapa Correction or not
bit2: Specify whether to mirror image invert the Ushape Correction of Even Number Chip
bit3: NotUsed
bit4~bit5: SW to select CRATIO_THERM_SEL
bit6~bit7: NotUsed
0
0
255
Select the IBY Vitta Correction Function
0: C_RATIO_CUL_S=CRATIO_SIGN
1: Integer part of C_RATIO_CUL_S =THERM_DELTA * THERM_K/64
2, 3: C_RATIO_CUL_S =NOD_LIGHTON_NUM[7: 0] * XTALK_M[7: 0]/64 Integer Part
650
0
2047
Coefficient to use when deriving USHAPE_A[0](calculation value), USHAPE_B[0](calcu-
lation value)
650
0
2047
Coefficient to use when deriving USHAPE_A[0](calculation value), USHAPE_B[0](calcu-
lation value)
650
0
2047
Coefficient to use when deriving USHAPE_A[0](calculation value), USHAPE_B[0](calcu-
lation value)
650
0
2047
Coefficient to use when deriving USHAPE_A[0](calculation value), USHAPE_B[0](calcu-
lation value)
0
0
2047
Comparison reference value with LPH_OUT_LOCAL.
0
0
2047
Comparison reference value with LPH_OUT_LOCAL.
0
0
2047
Comparison reference value with LPH_OUT_LOCAL.
0
0
2047
Comparison reference value with LPH_OUT_LOCAL.
19
0
255
Interval of 1 Line Lap (usec)
Idle Period=(LPH_HSYNC_BLANK+1)/10
0.1~25.5usec
05/2014
6-75
Write
Allowed/
Can be
Unit
Protected
initialized
-
O
O
-
O
O
100[ms] O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
6.3.10 NVM 749_LPH List
General

Advertisement

Table of Contents
loading

Table of Contents