NVM sum check value error.
Cause/Action
Turn the power off and on to check that the error recurs. Then, replace the ESS PWB.
problem cannot be solved, replace the printer.
117-365 Low Voltage
BSD-ON:-
RTC detected Low Voltage. RTC clock setting and content of SRAM are invalid. Initialize them.
Cause/Action
Turn the power off and on to check that the error recurs. Then,update to the latest F/W.If the problem
cannot be solved, replace the ESS PWB.
(PL
117-367 FXIF error
BSD-ON:-
An error occurred on FXIF (such as the Video Underrun error).
Cause/Action
Turn the power off and on to check that the error recurs. Then,update to the latest F/W. If the problem
cannot be solved, replace the following parts in sequence.
•
ESS PWB
(PL
18.2)
•
IIT
(PL
1.1)
(PL
18.2)
05/2014
2-110
18.2)If the
Troubleshooting
CHAIN 117