Chain-Link NVM Name
762-061
Auger Mark Countermeasure Temperature Thresh-
old Value
762-062
Auger Mark Countermeasure Humidity Threshold
Value
762-063
Auger Mark Countermeasure Time Threshold Value 45
762-064
Auger Mark Countermeasure YMC Time Threshold
Value Adjustment Ratio
762-065
Auger Mark Countermeasure Perform Time
762-080
Deve Low A/C Band Switch
762-081
Deve Low A/C Band Creation Interval
762-082
ADC MID Request Judgement Band Width Thresh-
old Value
762-083
High Load Determination No. of sheets
762-084
Mid Load Determination No. of sheets
762-085
Low R/L Determination Threshold Value
762-086
A4L Deve Cycle count Reduced Value (In High R/L
Mode)
762-087
A4L Deve Cycle count Reduced Value (In Low R/L
Mode)
762-088
Deve Low A/C Toner Band density
762-089
Deve Low A/C Toner Band Width Upper Limit
762-090
No. of Deve Low A/C Toner Band Created Y
762-091
No. of Deve Low A/C Toner Band Created M
762-092
No. of Deve Low A/C Toner Band Created C
762-093
No. of Deve Low A/C Toner Band Created K
762-094
Deve Low A/C Toner Band Width Integrated Value
Y
762-095
Deve Low A/C Toner Band Width Integrated Value
M
05/2014
6-174
Table 1 NVM 762_Deve 2 List
Default
Minimum
Maximum
Value
value
value
Description
27
0
100
Performance Determination Temperature Threshold Value for Auger Mark
Countermeasure
Perform when the temperature is above than this.
75
0
100
Performance Determination Humidity Threshold Value for Auger Mark
Countermeasure
Perform when the humidity is above than this.
0
2500
Performance Determination Time Threshold Value for Auger Mark Coun-
termeasure
Perform then the developing machine drive time with 63mm/s is more than
this threshold value.
50
1
100
YMC Auger Mark Countermeasure Time Threshold Value Adjustment
Ratio from Auger Mark Countermeasure of K is performed.
Make 1~100% of [Auger Mark Countermeasure Time Threshold Value].
40
1
100
No-Loading Time when Auger Mark Countermeasure is performed
1
0
2
Deve Low A/C Band Execution Selection Switch
0: Do not Execute, 1: Perform, 2: Perform with Control Mode]
Performance Judgement A/C Threshold Value, A/C Target Value changes
in Control Mode
40
0
200
ADC MID Demand determination Interval
1950
1000
10000
ADC MID Request Judgement Band Width Threshold Value. *Use only
when judging the MID SET Request when Deve Low A/C Band Determi-
nation Interval is reached
600
0
8000
High Load Mode Determination Threshold Value
100
0
8000
Mid Load Mode Determination Threshold Value
32
0
255
If the PV per 1 Job is lower than this Threshold Value, conduct the Deve
Low A/C Band Control in Low R/L Mode.
157
10
250
No. of Deve rotation equivalent to A4L (For High R/L Mode): FC_R/L100
Trial Calculation Value
(Used for Load Determination as well)
183
10
250
No. of Deve rotation equivalent to A4L (For Low R/L Mode): FC_R/L2 Trial
Calculation Value
100
60
100
Deve Low A/C Toner Band Density
2400
1000
10000
Deve Low A/C Toner Band Width Upper Limit
0
0
20000
No. of Deve Low A/C Toner Band Created * Clear with HFSI reset
0
0
20000
No. of Deve Low A/C Toner Band Created * Clear with HFSI reset
0
0
20000
No. of Deve Low A/C Toner Band Created * Clear with HFSI reset
0
0
20000
No. of Deve Low A/C Toner Band Created * Clear with HFSI reset
0
0
50000000
Deve Low A/C Toner Band Width Integrated Value. * Clear with HFSI
reset
0
0
50000000
Deve Low A/C Toner Band Width Integrated Value. * Clear with HFSI
reset
General
6.3.19 NVM 762_Deve 2 List
Write
Allowed/
Can be
Unit
Protected
initialized
Degree
O
O
%
O
O
Seconds
O
O
%
O
O
Seconds
O
O
-
O
O
PV
O
O
0.1[mm]
O
O
sheets
O
O
sheets
O
O
0.1
O
O
[sheets]
0.1[Cycle]
O
O
0.1[Cycle]
O
O
%
O
O
0.1[mm]
O
O
Times
O
O
Times
O
O
Times
O
O
Times
O
O
0.1[mm]
O
O
0.1[mm]
O
O

Advertisement

Table of Contents
loading

Table of Contents