Fuji Xerox DocuCentre SC2020 Service Manual page 611

Hide thumbs Also See for DocuCentre SC2020:
Table of Contents

Advertisement

Figure 8 j0bs64026
11. Press the [<--] (Back) button to return to the [Printer Diag] screen.
Figure 9 j0bs64016
12. Exit the CE mode. (See "6.4.4 How to Exit the CE Mode".)
Version 1.1
DC SC2020
6.4.8.3 Analog Input
A feature to check the Analog Input (AI) component works correctly.
If you run the analog input test, values are displayed in hexadecimal (16).
Analog input test will qualify all of AI components.
Table 1 Analig Input Parameter
Chain
Link
Parameter
010
200
Heat Roll NC Sensor: Inf
010
201
Heat Roll NC Sensor: Temp
010
202
Heat Roll NC Sensor: Diff
010
203
Heat Roll STS
071
200
Tray1 Size Sensor Analog
072
200
Tray2 Size Sensor Analog
089
200
R_RAD_LED (ADC Sensor)
089
202
R_RAD_LOW_LED (MOB Sensor)
Analog input test cases example
The following shows the example where a test is performed to check the 010-203: Heat Roll STS opera-
tion.
1.
Enter the CE Mode. (Refer to
"6.4.2
2.
Make sure [Printer Diag] is selected, and then press [OK] button.
3.
[Down arrow] "IOT Diag" button to select, and then press [OK] button.
4.
[Down arrow] "Analog Input" button to select, and then press [OK] button.
5.
Select "010-203" with the [Down arrow] button, and then press [OK] button.
05/2014
6-213
How to Enter the CE Mode")
Figure 1 j0bs64148
6.4.8.3 Analog Input
General

Advertisement

Table of Contents
loading

Table of Contents