9.1.7 Odor Filter Kit
Installation Kit
604K 91930
Installation Procedures
1.
Check the bundled items.
Table 1
No
Name
1
Odor Filter
2
Top Cover
2.
Turn OFF the Power Switch and make sure that power-saving LED and screen display turn OFF.
When turning OFF the power switch, check that the "Data" lamp is OFF and that there is no Job in
progress.
3.
Unplug the power plug.
When maintaining the machine, turn OFF the power switch and unplug the power plug.
4.
Open the Front Cover.
5.
Pull the Support (2) of the Front Cover. (Figure 1)
(1) Rotate the Support by 90 degrees and pull.
Figure 1 j0bs41905
6.
Remove the Front Cover. (Figure 2)
(1) Press the Stopper, move the Front Cover to the Left side and remove from the Boss.
Qty
1
1
CAUTION
WARNING
05/2014
9-28
7.
Remove the Waste Bottle. (Figure 3)
(1) Turn the Retract Handle in counter clockwise direction.
(2) Release the Hook (2).
(3) Remove the Waste Bottle.
8.
Remove the Pillar Left Cover. (Figure 4)
(1) Remove the Screw.
(2) Remove the Pillar Left Cover.
Installation/Removal
9.1.7 Odor Filter Kit
Figure 2 j0bs41906
Figure 3 j0bs40813