Figure 2 j0bs40601
5.
Remove the IBT Belt Unit. (Figure 3)
(1) Hold the Handle A and pull out the IBT Belt Unit where
Handle B can be seen.
(2) Hold the Handle B and Right Side Housing and remove
the IBT Belt Unit.
Figure 3 j0bs40602
6.
Remove the IBT Belt Cleaner. (Figure 4)
(1) Remove the screw.
(2) Remove the IBT Belt Cleaner.
05/2014
4-32
Figure 4 j0bs40604
7.
Replace with Belt Cleaner Blade in the Replacement Kit. (Fig-
ure 5)
(1) Remove the Tapping Screw (x2).
NOTE: Do not screw on too tightly when installing.
(2) Replace the Belt Cleaner Blade.
Figure 5 j0bs40605
Replacement
1.
Return the IBT Belt Cleaner to the original state.
2.
When installing the IBT Belt Unit, make sure the Retract Han-
dle is in the position as shown in the figure. (Figure 6)
Disassembly/Assembly and Adjustment
Figure 6 j0bs40603
3.
Return the IBT Belt Unit to the original state.
4.
Close the L/H Cover.
5.
Return the Waste Bottle to the original state.
6.
Close the Front Cover.
6. Transfer