DC SC2020
Version 1.1
Chain-Link NVM Name
749-429
HSYNC Fixed Mode
749-430
SOS_CYC_E0
749-431
SOS_CYC_E1
749-432
LPH_DOT_NUM_E0
749-433
LPH_DOT_NUM_E1
749-434
LPH_DOT_NUM_SUB_E0
749-435
LPH_DOT_NUM_SUB_E1
749-436
LPH_HSYNC_CYCLE_E0
749-437
LPH_HSYNC_CYCLE_E1
749-438
LPH_VDATA_CHK_COLOR
749-439
LPH_FAIL_LATCH_PRIORITY
749-440
LPH_YMC_INH_FAIL
749-441
LPH_YMC_INHIBIT_TRANS_GAP
749-442
LPH_PG_SEL_LM1
Table 1 NVM 749_LPH List
Default
Minimum
Maximum
Value
value
value
Description
0
0
255
When changing the Process Speed,
0: Set the Calculation Value to IBY.
1: Set the NVM Value to IBY.
30787
0
1048575
Setting Value of SOS Lap when light comes on during half speed
15393
0
1048575
Setting Value of SOS Lap when light comes on during full speed
32
10
255
Sets to IBY Register DOT_NUM when changing the process speed. (During half speed)
(When light goes on forcibly)
16
10
255
Sets to IBY Register DOT_NUM when changing the process speed. (During full speed)
(When light goes on forcibly)
173
0
255
Sets to IBY Register DOT_NUM_SUB when changing the process speed.
(When light goes on forcibly)(During half speed)
36
0
255
Sets to IBY Register DOT_NUM_SUB when changing the process speed.
(When light goes on forcibly)(During full speed)
8466
0
65535
Sets to IBY Register HSYNC_CYC_H,L when changing the process speed.
(When light goes on forcibly)(During half speed)
4233
0
65535
Sets to IBY Register HSYNC_CYC_H,L when changing the process speed.
(When light goes on forcibly)(During full speed)
3
0
3
When conducting Video Data Interruption Detection Sequence for 1 color, store the last
color.
0: Y, 1: M, 2: C, 3: K
27
0
255
Priority when there is multiple Latch Timing which was not determined as Fail/
Priority: bit0, 1
2nd Priority: bit2, 3
3rd Priority: bit4, 5
4th Priority: bit6, 7
3, 2, 1, 0 in the order of (default Value 11, 10, 01, 00)
= > 00 01 10 11 => 1B
0
0
1
0: The IBY Register accessed by this operation is not subject to read, write, ack Fail.
(Target Fail does not generate)
1: The IBY Register accessed by this operation is subject to read, write, ack Fail. (Target
Fail generates)
0
0
1
0: Do not switch the INHIBIT_TRANCE setting to YMC to by Page when Single K Print.
(Initial Value)
1: Switch the INHIBIT_TRANCE setting to YMC to by Page when Single K Print.
4
0
4
Color setting when printing in DC612 LPH Vitta Evaluation Chart (LM1)
0: Single Color Y, 1: Single Color M, 2: Single Color C, 3: Single Color K, 4: FC
05/2014
6-76
General
6.3.10 NVM 749_LPH List
Write
Allowed/
Can be
Unit
Protected
initialized
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O
-
O
O

Advertisement

Table of Contents
loading

Table of Contents