Chain-Link NVM Name
742-174
Regi Assist Start Timing Adjustment
(MSI/63[mm/s]/Extra Heavyweight)
742-175
Regi Assist Start Timing Adjustment
(MSI/63[mm/s]/Labels1)
742-176
Regi Assist Start Timing Adjustment
(MSI/126[mm/s]/Labels1)
742-177
Regi Assist Start Timing Adjustment
(MSI/63[mm/s]/Labels2)
742-178
Regi Assist Start Timing Adjustment
(Tray 2/126[mm/s]/Plain)
742-179
Regi Assist Start Timing Adjustment
(Tray 2/63[mm/s]/Extra Heavyweight)
742-180
Regi Assist Start Timing Adjustment
(Tray 2/126[mm/s]/Extra Heavyweight)
742-181
Regi Assist Start Timing Adjustment
(Tray 2/63[mm/s]/Extra Heavyweight)
742-182
Regi Assist Start Timing Adjustment
(Tray2/63[mm/s]/Labels1)
742-183
Regi Assist Start Timing Adjustment
(Tray2/126[mm/s]/Labels1)
742-184
Regi Assist Start Timing Adjustment
(Tray2/63[mm/s]/Labels2)
742-185
Regi Assist Start Timing Adjustment
(Duplex/126[mm/s]/Plain);
742-186
Regi Assist Start Timing Adjustment
(Duplex/63[mm/s]/Heavyweight);
742-187
Regi Assist Start Timing Adjustment
(Duplex/126[mm/s]/Heavyweight);
742-188
Regi Assist Start Timing Adjustment
(Invert/126[mm/s]/Plain)
742-189
Regi Assist Start Timing Adjustment
(Invert/63[mm/s]/Heavyweight1)
742-190
Regi Assist Start Timing Adjustment
(Invert/126[mm/s]/Heavyweight1)
Version 1.1
DC SC2020
Table 1 NVM 742_Paper Handling List
Default
Minimum
Maximum
Value
value
value
Description
0
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (MSI/63[mm/s]/Extra Heavy-
weight)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
0
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (MSI/63[mm/s]/Labels1)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
0
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (MSI/126[mm/s]/Labels1)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
0
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (MSI/63[mm/s]/Labels2)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
0
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (Tray2/126[mm/s]/Plain)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
0
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (Tray2/63[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
0
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (Tray2/126[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
0
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (Tray2/63[mm/s]/Extra Heavy-
weight)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
0
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (Tray2/63[mm/s]/Labels1)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
0
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (Tray2/126[mm/s]/Labels1)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
0
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (Tray2/63[mm/s]/Labels2)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
0
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (Duplex/126[mm/s]/Plain)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
0
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (Duplex/63[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
0
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (Duplex/126[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
-18
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (Invert/126[mm/s]/Plain)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
28
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (Invert/63[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
-18
-127
127
Adjusts the Assist Operation start timing when Regi is ejected (Invert/126[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
05/2014
6-49
Write
Allowed/
Can be
Protected
initialized
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O