Checking The Tightness Of Fastening Bolts - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Vertical mounting position (IM V.)
Table 11- 19 Grease service life in operating hours [h] with permanent lubrication
Frame size Motor speed n
71
80
90
100
112
132
11.2.18

Checking the tightness of fastening bolts

Note
Replace damaged headless bolts with new bolts of the same type and strength class.
Switch off the power supply to the drive unit. Check all fastening bolts for tightness using a
torque wrench.
The general tolerance for the tightening torque in Nm is 10 %. The friction coefficient is
0.14 μ.
Table 11- 20 Tightening torques for fastening bolts
Thread size
M4
M5
M6
M8
M10
M12
M16
M20
M24
M30
M36
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
in rpm
N
3 600
3000
1800
Operating hours in h
24000
33000
33000
24000
17000
17000
24000
12000
Tightening torque for strength class
8.8
Nm
3
6
10
25
50
90
210
450
750
1500
2 500
Additional information on the SIMOGEAR geared motor
1500
1200
33000
33000
24000
10.9
Nm
4
9
15
35
70
120
295
580
1 000
2 000
3 600
11.2 Specific data motor
Grease quantity in
the bearing
≤ 1 000
D-end
ND-end
g
33000
9
9
15
11
20
15
45
25
75
50
12.9
Nm
5
10
18
41
85
145
355
690
1200
2 400
4 200
425

Advertisement

Table of Contents
loading