Nortel DMS-100 Series Maintenance Manual page 302

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-114 RLCM-EDC card replacement procedures
NT6X74
in RMM
(continued)
Summary of replacing an NT6X74 card in RMM
At the TRKS;TTP
level, post the RMM
Are the RMM
trunks ManB?
N
Busy the trunks that
associate with the
RMM
At PM level, post
and busy the RMM
297-8381-550 Standard 02.02 April 1999
Y
Replace card with a
card that has an
identical PEC
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.
At PM level, post
and load the RMM
Return the RMM to
service
At TTP level, post
the RMM and return
trunks to service
End of procedure

Advertisement