11
Determine the type of device that holds the PM load files.
If load files
are on tape
are on IOC disk
are on SLM disk
12
Locate the tape that contains the PM load files.
13
Mount the tape on a magnetic tape drive.
14
To download the tape, type
>MOUNT tape_no
and press the Enter key.
where
tape_no
is the number of the tape drive that contains the PM load files.
15
To list the contents of the tape in your user directory, type
>LIST T tape_no
and press the Enter key.
where
tape_no
is the number of the tape drive that contains the PM load files.
16
To demount the tape drive, type
>DEMOUNT T tape_no
and press the Enter key.
where
tape_no
is the number of the tape drive that contains the PM load files.
Proceed to step 27.
17
From office records, determine and note the number of the input/output
controller (IOC) disk. Determine the name of the volume that contains the PM
load files.
18
To access the disk utility level of the MAP display, type
>DSKUT
and press the Enter key.
RLCM-EDC card replacement procedures 6-117