Nortel DMS-100 Series Maintenance Manual page 203

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP display
45
Post the LCM that is controlled by the alarm and control card you have just
replaced by typing
>POST LCM site cabinet lcm
and pressing the Enter key.
where
site
is the site name of the RLCM-EDC (alphanumeric)
cabinet
is the cabinet number of the RLCC-EDC
lcm
is the number of the LCM
46
Return LCM unit 0 to service by typing
>RTS UNIT 0
and pressing the Enter key.
If unit 0
RTS passed
RTS failed
47
Load the standby bank of LCM unit 0 by typing
>LOADPM UNIT 0 CC
and pressing the Enter key.
If
load passed
load failed
48
Return LCM unit 0 to service and activate the load in the standby bank by
typing
>RTS UNIT 0 SWLD
and pressing the Enter key.
If unit 0
RTS passed
RTS failed
RLCM-EDC card replacement procedures 6-15
Do
step 49
step 47
Do
step 48
step 53
Do
step 49
step 53
DMS-100 Family Maintenance Manual ABSK007
NT0X91
in FSP
(continued)