Nortel DMS-100 Series Maintenance Manual page 166

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

5-52 RLCM-EDC alarm clearing procedures
PM RMM
major
(continued)
At the MAP terminal
11
12
13
14
15
16
17
18
297-8381-550 Standard 02.02 April 1999
To download the tape, type
>MOUNT tape_no
and press the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
To list the contents of the tape in the user directory, type
>LIST T tape_no
and press the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
To demount the tape drive, type
>DEMOUNT T tape_no
and press the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
Go to step 24.
From office records, determine and note the number of the input/output
controller (IOC) disk. Determine the name of the volume containing the PM
load files.
To access the disk utility level of the MAP, type
>DSKUT
and press the Enter key.
To list the IOC file names in your user directory, type
>LISTVOL volume_name ALL
and press the Enter key.
where
volume_name is the name of the volume containing the PM load files obtained
in step 15
To leave the disk utility, type
>QUIT
and press the Enter key.

Advertisement

Table of Contents
loading

Table of Contents