Nortel DMS-100 Series Maintenance Manual page 29

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

The following response is observed for the LOADPM command when the
mate unit is OOS and the SELFACT option is used. When this response is
observed, operating company personnel must RTS the OOS unit then
execute the LOADPM command with the SELFACT option.
>LOADPM UNIT 1 SELFACT
Example of MAP response
LCM REM1 0 0 Unit 1
The following response is observed for the LOADPM command when the
SELFACT option is performed on a SMEM (64K/256K) LCM. The
operating company personnel must retry the command without the
SELFACT option.
>LOADPM UNIT 1 SELFACT
or
>LOADPM PM SELFACT
Example of MAP response
SELFACT option invalid. See HELP LOADPM
The LOADPM command takes significantly longer to complete on
RLCM-EDC nodes compared to existing LCM nodes, due to the size of the
new software load for the RLCM-EDC product.
Limitations
The following limitations must be ahered to when using the
command for an RLCM-EDC:
The loadfile name is obtained from table LCMINV when the load source
specified is CC. This is overridden when the name of the loadfile is
provided as a parameter of the command string.
When the specified load source is MATE, the load is obtained from
either the active or standby bank of the mate unit, depending on the
suboption used,
ACT
The
command with
LOADPM
suboption is specified.
When the specified source is
of the active bank are copied into the standby bank of the same unit.
The
option is not valid for the RLCM-EDC.
NOCHECK
Request Invalid
Unit must be InSv/ISTb for SELFACT option
or
.
STBY
option defaults to the
MATE
SELFACT
DMS-100 Family Maintenance Manual ABSK007
Maintenance overview 1-17
LOADPM
STBY
and the unit is InSv, the contents
bank if no