6
To display P-side link information, type
> TRNSL P
and press the Enter key.
Example of a MAP response:
Link 2: LCM REM1 00 0
Link 6: LCM REM1 00 0
7
Record the numbers of the links with status not OK.
Use the following diagram to determine which DS-1 interface card or cards
correspond to the links identified as defective in step 6. Note that each NT6X50
card has two ports. For example, the defective link 6 that appears in step 6
connects to port 1 as indicated. Port 1 corresponds to the NT6X50 in slot 20.
Port numbers
Slot numbers
8
Determine the slot location of the defective card.
If defective card
is in slot 19 or 20 of the HIE
is in slot 21 of the HIE
RLCM-EDC card replacement procedures 6-81
RLCM-EDC C-side port numbers
0;Cap MS;Status:OK
1;Cap MS;Status:SysB ;MsgCond: CLS
6
6
6
X
X
X
5
5
5
0
0
0
0
1
4
2
3
5
19
20
21
Do
step 9
step 12
DMS-100 Family Maintenance Manual ABSK007
NT6X50
in HIE
(continued)
;MsgCond: OPN