4-10 RLCM-EDC recovery procedures
RLCM-EDC recovery procedure
18
19
297-8381-550 Standard 02.02 April 1999
To post the host LTC+ links to the RLCM-EDC and check link conditions for
slips and framing errors, type
>POST LTC ltc_no link_no
and pressing the Enter key.
where
pm_no
is the number of the LTC+ (0 to 255)
link_no
is the number of the link associated with the host LTC+
(refer to step 16 display)
Note: Repeat the POST command for each link on the RLCM-EDC.
Example of a MAP response:
N CLASS
SITE
LTC CK D ALRM SLIP FRME
0 REMOTE HOST
Note: This display shows carrier facilities from the host LTC+ to the
RLCM-EDC. Use the Detail REM option to check the carrier facilities from the
remote site back to the host LTC+.
If link conditions
show a high number of SLIP and
FRME
show a very low number of SLIP
and FRME
To post the RLCM-EDC, type
>PM;POST LCM site cabinet lcm
press the Enter key.
where
site
is the site name of the RLCM-EDC (alphanumeric)
cabinet
is the cabinet number of the RLCC-EDC
lcm
is the number of the LCM
(continued)
Host LTC P-side link number
1
0
C
0
Do
step 25
step 19
BER ES
SES STATE
0
<–7. 0
0
INSV