Nortel DMS-100 Series Maintenance Manual page 243

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

29
To return the LCM unit to service, type
>RTS UNIT 0
and press the Enter key.
If RTS
passes
fails
At the MAP display
30
To busy unit 1 of the RLCM-EDC, type
>BSY UNIT 1
and press the Enter key.
At the HIE shelf
31
WARNING
Static electricity damage
Wear a wrist strap that connects to the wrist strap
grounding point of a frame supervisory panel (FSP)
when you handle circuit cards. This action protects
the cards against static electricity damage.
Power down the NT2X70 card in slot 22 of the HIE shelf. To power down the
card, set the ON/OFF switch on the power converter faceplate to OFF. Both the
converter FAIL LED and FRAME FAIL lamp on the frame supervisory panel
(FSP) will be ON. An audible alarm can sound. If an alarm sounds, silence it.
To silence the alarm, type
>SIL
and press the Enter key.
If NT2X70 is in
shelf 33 slot 25
shelf 33 slot 22
32
To replace the NT2X70 card in slot 22 use the procedure "Replacing a card".
Complete the procedure and return to this point.
RLCM-EDC card replacement procedures 6-55
Do
step 36
step 39
trip circuit breaker
CB3 on FSP
CB8 on FSP
DMS-100 Family Maintenance Manual ABSK007
NT2X70
in HIE
(continued)