Nortel DMS-100 Series Maintenance Manual page 242

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-54 RLCM-EDC card replacement procedures
NT2X70
in HIE
(continued)
22
23
24
25
26
27
28
297-8381-550 Standard 02.02 April 1999
Go to step 28.
From office records, determine and note the number of the system load module
(SLM) disk. Determine the name of the volume that contains the PM load files.
Access the disk utility level of the MAP, type
>DISKUT
and press the Enter key.
To list the SLM disk volume names, type
>LV CM
and press the Enter key.
To list the SLM file names into your user directory, type
>LF volume_name
and press the Enter key.
where
volume_name is the name of the volume that contains the PM load files,
obtained in step 23
To leave the disk utility, type
>QUIT
and press the Enter key.
To load LCM unit 0, type
>LOADPM UNIT 0 CC
and press the Enter key.
If the LOADPM
passes
fails
Do
step 29
step 39

Advertisement

Table of Contents
loading