Nortel DMS-100 Series Maintenance Manual page 287

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT6X53 card in an LCM
At your current location
1
Proceed to step 2 if one of the following conditions applies:
another maintenance procedure directed you to this card replacement
procedure
you use this procedure to verify or accept cards
your maintenance support group directed you to this procedure
2
Obtain a replacement card. Make sure that the replacement card has the same
product equipment code (PEC) and suffix as the card to remove.
At the MAP display
3
To access the peripheral module (PM) level of the MAP terminal and post the
line concentrating module (LCM), type
>MAPCI;MTC;PM;POST LCM site cabinet lcm
and press the Enter key.
where
site
is the name of the RLCM-EDC site (alphanumeric)
cabinet
is the number of the RLCC-EDC cabinet
lcm
is the number of the LCM
Example of a MAP display:
LCM
Rem1
OO O ISTb
Unit 0:
InSv
Unit 1:
SysB
Drwr: 01 23 45 67 89 01 23 45 67 89
.. .. .. .. .. .. .. .. .. ..
4
To busy the LCM unit that contains the defective card, type
>BSY UNIT unit_no
and press the Enter key.
where
unit_no
is the LCM unit (0 or 1) to busy
RLCM-EDC card replacement procedures 6-99