10-4 Advanced troubleshooting procedures
13 Refer to the table, FSP circuit breaker assignments, in step 3. Set the
14 To query the PM for valid loadfiles, type
15 To return to service the LCM part of the RLCM-EDC, type
16 To post the RMM part of the RLCM-EDC, type
17 To busy the RMM, type
18 Refer to the table, FSP circuit breaker assignments, in step 3. Set the CB
19 Push in and hold the reset switch of either power converter. Set the CB
20 To list the peripheral module (PM) loads at the input-output (IO) device
297-8381-550 Standard 02.02 April 1999
CBs for the NT6X53AA power converters in shelf positions 5 and 19 to
the ON position.
>QUERYPM OOS
and press the Enter key.
>RTS PM
and press the Enter key.
>POST RMM rmm_no
and press the Enter key.
>BSY
and press the Enter key.
for the NT2X09AA and NT2X06AB power converters in shelf position
47 to the ON position.
Note: Both power converters are powered through the same CB.
to the ON position and release the CB and reset switch.
that you want to use, RTS the units. To perform the following action if
this action was not performed during the power up procedure, type:
>DSKUT;LISTVOL volume name ALL
and press the Enter key.
or, to load from a DMS Supernode, type:
>DISKUT;LV CM;LF volume name
and press the Enter key.
where
volume name is the volume where the PM loads are located

Advertisement