RLCM-EDC recovery procedure
RLCM-EDC recovery procedure
At the MAP terminal
1
To silence an audible alarm, type
>MAPCI;MTC;SIL
and press the Enter key.
2
To access the peripheral module (PM) level of the MAP display, type
>PM
and press the Enter key.
3
To identify the defective RLCM-EDC, type
>DISP STATE CBSY LCM
and press the Enter key.
If response
indicates no CBsy LCMs
indicates CBsy LCMs
4
To post the RLCM-EDC with the alarm condition, type
>POST LCM CBSY
press the Enter key.
Note: Note the name and number of this RLCM-EDC.
5
To identify the control side (C-side) links to the host Line Trunk Controller PLUS
(LTC+), type
>TRNSL C
and press the Enter key.
Example of a MAP response:
Link 0:
LTC 1 2;Cap MS;Status: SysB ;MsgCond: CLS
Link 1: LTC 1 6;Cap MS;Status: SysB ;MsgCond: CLS
6
To post the host LTC+, type
>POST LTC ltc_no
and press the Enter key.
where
ltc_no
RLCM-EDC recovery procedures 4-5
Do
step 11
step 4
is the number of the LTC+ (0 to 255)
DMS-100 Family Maintenance Manual ABSK007