Nortel DMS-100 Series Maintenance Manual page 296

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-108 RLCM-EDC card replacement procedures
NT6X54
NT6X54
in LCM
in LCM
(continued)
(end)
17
18
19
20
21
297-8381-550 Standard 02.02 April 1999
To test the RLCM-EDC unit, type
>TST UNIT unit_no
and press the Enter key.
where
unit_no is the number of the LCM unit (0 or 1) that associates with the new
NT6X54 card.
If the TST
passes
fails
Send defective cards for repair according to local procedure.
Record the items that follow in office records:
date that card replacement occurs
serial number of the card
indications that prompt replacement of the card
Proceed to step 21.
For additional help, contact the next level of maintenance.
The procedure is complete.
Do
step 18
step 20

Advertisement

Table of Contents
loading