6-64
6-64
RLCM-EDC card replacement procedures
NT3X09
in RMM
Application
Use this procedure to replace a card in the shelves or frames identified in the
following table.
PEC
NT3X09
If you cannot identify the PEC, suffix, and shelf or frame for the card you
want to replace, refer to the Index. The maintenance manual index contains a
list of cards, shelves, and frames.
Common procedures
This procedure contains the reference "Replacing an NT3X09 card."
Action
This procedure contains a summary flowchart and a list of steps. Use the
flowchart to review the procedure. Follow the steps to perform the
procedure.
297-8381-550 Standard 02.02 April 1999
6-64
Suffixes
Cardname
AA, BA
Metallic Test Access
(MTA)
Shelf/frame name
RMM/RLCC