Nortel DMS-100 Series Maintenance Manual page 137

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

14
To RTS the busied unit, type
>RTS UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the LCM unit to be tested (0 or 1)
If RTS
passes
fails because of a loading error
fails, and a card list appears
fails, and a card list does not
appear
15
To attempt to load the RLCM-EDC unit, type
>LOADPM UNIT lcm_unit CC
and press the Enter key.
where
lcm_unit
is the LCM unit to be loaded (0 or 1)
Example of a MAP response:
LCM REM1 0 0 Unit 0 loadPM Passed.
If loading
passes
fails
16
To attempt to return the RLCM-EDC unit to service and switch load to the
standby bank, type
>RTS UNIT lcm_unit SWLD
and press the Enter key.
where
RLCM-EDC alarm clearing procedures 5-23
Do
step 20
step 15
step 17
step 18
Do
step 16
step 18
DMS-100 Family Maintenance Manual ABSK007
PM LCM
major
(continued)