7 To translate the P-side links of the LCM that interface the RMM, type
8 To access the TRKS;TTP level of the MAP display and post the RMM of
9 To installation busy all RMM trunks, type
10 To access the PM level of the MAP display and to post the RMM of the
11 To busy the RMM ,type
12 Refer to the table, FSP circuit breaker assignments, in step 4 and set the
13 You powered down the RMM.
14 The procedure is complete.

Common procedures

Some common troubleshooting procedures are in the following sections for
loading, RTS, dial tone, and ringing generators.

Troubleshooting a loading failure

The following procedure outlines the steps to troubleshoot a failure to load
the peripheral program files for the RLCM-EDC.
1 Verify that blown fuses are not present and that power converters are
>TRNSL P
the RLCM-EDC, type
>TRKS;TTP;POST RMM rmm_no
and press the Enter key.
where
rmm_no is the number of the RMM posted in step 7
>BSY INB ALL
RLCM-EDC, type
>PM;POST RMM rmm_no
and press the Enter key.
where
rmm_no is the number of the RMM step 7 identifies
>BSY
and press the Enter key.
CB for the NT2X06AB and NT2X09AA power converters in shelf
position 47 to the OFF position.
powered up and supply the correct voltages.
Advanced troubleshooting procedures 10-7
DMS-100 Family Maintenance Manual ABSK007