Nortel DMS-100 Series Maintenance Manual page 175

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Clearing a PM LCM minor alarm
At the MAP terminal
1
To silence an audible alarm, type
>MAPCI;MTC;SIL
and press the Enter key.
2
To access the PM level of the MAP display, type
>PM
and press the Enter key.
3
To identify the RLCM-EDC that has faults, type
>DISP STATE ISTB LCM
and press the Enter key.
4
To post the RLCM-EDC with the alarm condition, type
>POST LCM site cabinet lcm
and press the Enter key.
where
site
is the site name of the RLCM-EDC (alphanumeric)
frame
is the cabinet number of the RLCC-EDC
lcm
is the number of the LCM
5
To determine the fault indicators, type
>QUERYPM FLT
and press the Enter key.
If the system
indicates a CBsy (C-side busy)
fault
indicates a PBsy (P-side busy)
fault
indicates a DRWR FLT (drawer
fault)
indicates an ISTb (In-service
trouble) fault
RLCM-EDC alarm clearing procedures 5-61
Do
step 6
step 12
step 18
step 22
DMS-100 Family Maintenance Manual ABSK007
PM LCM
minor
(continued)