Nortel DMS-100 Series Maintenance Manual page 107

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

RLCM-EDC recovery procedure
10
To return the busy link to service (RTS), type
>RTS LINK link_no
and press the Enter key.
where
link_no
is the number of a defective P-side link tested in step 9
Note: Repeat this step for each tested link.
If RTS
passed and other links are not SysB
passed but other links are SysB
failed
11
To identify the defective RLCM-EDC at the peripheral module (PM) level of the
MAP display, type
>DISP STATE SYSB LCM
and press the Enter key.
If MAP response
indicates no SysB LCMs
indicates SysB LCMs
12
To post the RLCM-EDC with the alarm condition, type
>POST LCM SYSB
and press the Enter key.
RLCM-EDC recovery procedures 4-7
Do
step 11
step 8
step 24
Do
step 32
step 12
DMS-100 Family Maintenance Manual ABSK007
(continued)