Nortel DMS-100 Series Maintenance Manual page 180

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

5-66 RLCM-EDC alarm clearing procedures
PM LCM
minor
(continued)
20
21
297-8381-550 Standard 02.02 April 1999
Note: Repeat this step for the other line subgroup associated with the drawer
that has faults.
To test both line subgroups associated with the drawer that has faults, type
>TST DRWR lsg
and press the Enter key.
where
lsg
is the number of one of the line subgroups associated with the
drawer that has faults.
Note: Repeat this step for the other line subgroup associated with the drawer
that has faults.
If test
passed
failed, and the system produces a
card list
failed, but the system does not
produce a card list
To return to service both line subgroups, type
>RTS DRWR lsg
and press the Enter key.
where
lsg
is the number of one of the line subgroups associated with the
drawer that has faults
Example of a MAP response:
OSvce Tests Initiated
LCM
REM1 00 0
LCM
REM1 00 0
Note: Repeat this step for the other line subgroup associated with the drawer
that has faults.
If return to service
passed
failed
Do
step 21
step 25
step 26
Drwr 2 Tst Passed
Drwr 2 Rts Passed
Do
step 28
step 26