6-50 RLCM-EDC card replacement procedures
NT2X70
in HIE
(continued)
Replacing an NT2X70 card in HIE shelf,
At your current location
1
2
At the MAP display
3
4
297-8381-550 Standard 02.02 April 1999
Proceed to step 2 if one of the following conditions applies:
another maintenance procedure directed you to this card replacement
procedure
you use the procedure to verify or accept cards
your maintenance support group directed you to this procedure
Obtain a replacement card. Make sure that the replacement card has the same
product equipment code (PEC), including suffix, as the card you remove.
To access the peripheral module (PM) level of the MAP display and post the
Remote Line Concentrating Module with Extended Distance Capability
(RLCM-EDC) associated with the defective NT2X70 card, type:
>MAPCI;MTC;PM;POST LCM site cabinet lcm
and press the Enter key.
where
site
is the name of the site where the RLCM-EDC is
cabinet
is the number of the cabinet where the LCM is
lcm
is the number of the LCM module in the cabinet
If the NT2X70 card
is in slot 25
is in slot 22
To display the P-side links of the RLCM, type
>TRNSL P
and press the Enter key.
Example of a MAP display:
Link
0:
RMM 0
Link
1:
RMM 0
Do
step 4
step 30
0;
Cap MS;Status:
1;
Cap MS;Status:
OK; MsgCond:OPN
OK; MsgCond:OPN