Nortel DMS-100 Series Maintenance Manual page 177

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

10
To test the busied link, type
>TST LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link busied in step 9
If test
passed
failed
11
To return the busied link to service, type
>RTS LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link tested in step 10
If RTS
passed and no other links are
SysB
passed but other links are SysB
failed
12
To display P-side links, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
Link
0: RMM 0
Link
1: RMM 0
RLCM-EDC alarm clearing procedures 5-63
Do
step 11
step 18
Do
step 17
step 9
step 18
0;Cap MS;Status:PBsy ,P;MsgCond:CLS
1;Cap MS;Status:PBsy ,P;MsgCond:CLS
DMS-100 Family Maintenance Manual ABSK007
PM LCM
minor
(continued)