Nortel DMS-100 Series Maintenance Manual page 271

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Change dip switch settings on the new replacement card to match the defective
card that you remove.
14
Use the procedure "Replacing a card" to replace the NT6X50 card. When the
card replacement is complete, return to this point.
At the MAP display
15
To test the links busied in step 12, type
>TST LINK link_no
and press the Enter key.
where
link_no
is one of two links associated with the replacement card
Note: Repeat this step for the other link associated with the replacement
card.
If test
failed
passed
16
To return to service the links busied in step 12, type
>RTS LINK link_no
and press the Enter key.
where
link_no
is one of two links associated with the replacement card
Note: Repeat this entry for the other link associated with the replacement
card.
If RTS
failed
passed
RLCM-EDC card replacement procedures 6-83
Do
step 24
step16
Do
step 24
step17
DMS-100 Family Maintenance Manual ABSK007
NT6X50
in HIE
(continued)

Advertisement

Table of Contents
loading