Nortel DMS-100 Series Maintenance Manual page 241

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP display
14
To download the tape, type
>MOUNT tape_no
and press the Enter key.
where
tape_no
is the number of the tape drive that contains the PM load files
15
To list the contents of the tape in your user directory, type
>LIST T tape_no
and press the Enter key.
where
tape_no
is the number of the tape drive that contains the PM load files
16
To release the tape drive from your user directory, type
>DEMOUNT T tape_no
and press the Enter key.
where
tape_no
is the number of the tape drive mounted in step 14
17
Go to step 28.
18
From office records, determine and note the number of the input/output
controller (IOC) disk. Determine the name of the volume that contains the PM
load files.
19
To access the disk utility level of the MAP, type
>DSKUT
and press the Enter key.
20
To list the IOC file names into your user directory, type
>LISTVOL volume_name ALL
and press the Enter key.
where
volume_name is the name of the volume that contains the PM load files,
obtained in step 18
21
To leave the disk utility, type
>QUIT
and press the Enter key.
RLCM-EDC card replacement procedures 6-53
DMS-100 Family Maintenance Manual ABSK007
NT2X70
in HIE
(continued)

Advertisement

Table of Contents
loading

Table of Contents