7
Post the RLCM-EDC that is controlled by the alarm and control card as
recorded in step 5 by typing
>POST LCM site cabinet lcm
and pressing the Enter key.
where
site
is the site name of the RLCM-EDC (alphanumeric)
cabinet
is the cabinet number of the RLCC-EDC
lcm
is the number of the LCM
If Converter suffix is
AA
AE
8
Busy LCM unit 1 by typing
>BSY UNIT 1
and pressing the Enter key.
At the RLCC cabinet
9
Put on a wrist strap.
10
Set CB8 as recorded in step 4 to the OFF position.
11
Unscrew the slotted nut located on the left-hand side of the FSP.
12
DANGER
Risk of electrocution
Some of the terminals inside the frame supervisory
panel (FSP) have an electrical potential of
–48 V dc. Remove all jewelry before replacing a card
in the FSP. Do not touch any terminals in the FSP.
Open the FSP panel.
13
Remove the NT0X91AA card from the slot identified in step 2.
14
Insert the replacement card.
15
Close the FSP panel.
RLCM-EDC card replacement procedures 6-11
Do
step 8
step 24
DMS-100 Family Maintenance Manual ABSK007
NT0X91
in FSP
(continued)