Nortel DMS-100 Series Maintenance Manual page 179

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

17
To post the RLCM-EDC with the alarm condition, type
>POST LCM site cabinet lcm
and press the Enter key.
where
site
is the site name of the RLCM (alphanumeric)
frame
is the cabinet number of the RLCC-EDC
lcm
is the number of the LCM
18
CAUTION
If you do not allow the time required for the system to
clear the alarm, a false alarm indication can occur.
Allow 3 to 5 min for the system to clear the alarm
before you proceed to the next step.
Determine if the problem is a drawer that has faults. Letters under the line
subgroup numbers associated with a physical drawer indicate a drawer that has
faults.
Example of a MAP response:
LCM
REM1 00 0
Unit0: InSv
Unit1: InSv
Drwr:
01 23 45 67 89 01 23 45 67 89
.. SS .. .. .. .. .. .. .. ..
If the system
indicates a drawer that has faults
does not indicate a drawer that
has faults
19
To busy both line subgroups associated with the drawer that has faults, type
>BSY DRWR lsg
and pressing the Enter key.
where
lsg
is the number of the line subgroups associated with the drawer that
has faults
RLCM-EDC alarm clearing procedures 5-65
ISTb
Links OOS: Cside
11 11 11 11 11 RG: Unequip
Do
step 19
step 22
DMS-100 Family Maintenance Manual ABSK007
PM LCM
minor
(continued)