Nortel DMS-100 Series Maintenance Manual page 114

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

4-14 RLCM-EDC recovery procedures
RLCM-EDC recovery procedure
RLCM-EDC recovery procedure
31
Existing loads: Unit 0: Act:REDC07AA *FLT*
New loads after a successful RTS will be:
Do you wish to continue?
Please confirm ("YES", "Y", "NO", or "N"):
>Y
32
297-8381-550 Standard 02.02 April 1999
To attempt to return the LCM unit to service and switch load to standby bank,
type
>RTS UNIT lcm_unit SWLD
press the Enter key.
where
lcm_unit
is the LCM unit to be returned to service (0 or 1)
Example of a MAP response:
Unit 0: Act:REDC07AA
If RTS
passes
fails
The procedure is complete. If the system displays additional alarms, proceed
to the appropriate Alarm and Clearing Procedure .
(end)
(continued)
Stby:REDC07AA *FLT*
Do
step 32
step 24
Stby:REDC07AA

Advertisement

Table of Contents
loading

Table of Contents