Nortel DMS-100 Series Maintenance Manual page 108

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

4-8 RLCM-EDC recovery procedures
RLCM-EDC recovery procedure
13
14
PM Type: LCM
LCM REM1 02 0
ESA equipped: No, Intraswitching is Off
Loadname: LCMINV – REDC07AA
Unit0 Loads: Act– REDC07AB *FLT* Stby– REDC07AA
Unit1 Loads: Act– REDC07AB *FLT* Stby– REDC07AA
REX is ON; INCOMPLETE on SAT. 1995/10/28 at 01:35:19
Node Status: {MAN_BUSY, FALSE}
Unit 0 Status: {MAN_BUSY, FALSE}
Unit 1 Status: {MAN_BUSY, FALSE}
Site Flr RPos
REM1
Services : NEUTRAL
15
297-8381-550 Standard 02.02 April 1999
To busy both LCM units of the RLCM-EDC, type
>BSY PM
and press the Enter key.
To query the out-of–service (OOS) LCM for correct load information, type
>QUERYPM OOS
and press the Enter key.
Example of a MAP response:
Int. No.: 9
Memory Size – Unit 0: 4M , Unit 1: 4M
Bay_id
01
K03
RLCM 02
If loadfiles
are valid
are invalid
To RTS the PM, type
>RTS PM
are press the Enter key.
If RTS
passes
fails
(continued)
Status index: 7
Shf
Description
04
LCM
02 0
Do
step 15
step 22
Do
step 32
step 16
Node_No: 40
Slot
EqPEC
6X04AA