Nortel DMS-100 Series Maintenance Manual page 255

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the RLCC cabinet
6
WARNING
Static electricity damage
Wear a wrist strap that connects to the wrist-strap
grounding point of a frame supervisory panel (FSP) to
handle circuit cards. The wrist strap protects the cards
against static electricity damage.
To replace the NT3X09 card, use the procedure "Replacing an NT3X09 card".
When the procedure is complete, return to this point.
At the MAP terminal
7
To post the new NT3X09 card, type
>POST P RMM rmm_no ckt_no
and press the Enter key.
where
rmm_no
is the number of the RMM shelf, the location of the card to remove
ckt_no
is the number of the first circuit and the location of the NT3X09 card
8
To return to service the circuits used in step 5, type
>RTS ;NEXT
and press the Enter key.
Note: Repeat this step for all circuits that associate with the new NT3X09 card.
If RTS
passes
fails
9
To send defective cards for repair, follow the local procedures.
10
Record information for office records, as follows:
date of card replacement
serial number of the card
details and reasons for replacement of the card
Go to step 12.
RLCM-EDC card replacement procedures 6-67