Nortel DMS-100 Series Maintenance Manual page 249

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP display
9
To post the trunk circuits that associate with the new NT2X90 card,
>POST P RMM rmm_no ckt_no ckt_no
and press the Enter key.
where
rmm_no
is the number of the RMM that contains the new NT2X90 card
ckt_no
is the number of the first circuit that associates with the new card
ckt_no
is the number of the last circuit that associates with the new card
Example of a MAP response:
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
RMM 0 0
10
To place the first circuit on hold and test the second circuit,
>HOLD
and press the Enter key,
and then type
>TST
and press the Enter key
If the TST
passed
failed
RLCM-EDC card replacement procedures 6-61
MONTALK
BUSY Q
COM LANG
MONTALK
21
DMS-100 Family Maintenance Manual ABSK007
in RMM
(continued)
DIG
STA S R DOT TE R
MB
type:
Do
step 11
step 19
NT2X90
type:

Advertisement

Table of Contents
loading

Table of Contents