RTS command error messages The RTS command rejects any attempt
to return to service a unit which has an invalid load in the active and standby
banks. A new response is generated when attempting to RTS a RLCM-EDC
unit which has an invalid load in the active and standby banks. When this
response is observed the operating company personnel can try the RTS
command with the SWLD option. If the same response is obtained for the
SWLD option also, the operating company personnel will have to load the
unit with a valid load using the LOADPM command. After loading, the unit
can be returned to service with the RTS SWLD command.
The following response is observed when an attempt is made to RTS an
RLCM-EDC unit with an invalid load in the active bank.
>RTS UNIT 0
>RTS UNIT 0 SWLD
Example of MAP response
LCM REM1 01 0 Unit 0 Invalid Active load.
The following table, "Options of the RTS command," describes RTS
command options as related to the RLCM-EDC product.
Options of the RTS command
Command
Option
RTS
ALL
RTS
SMEM
RTS
SWLD
or
Use QueryPM to check loads.
Description
This option allows operating company personnel to
execute the RTS command on a set of posted LCMs.
This option is use with the ALL option when preparing to
RTS a set of posted LCMs (64K, and 256K). The
command returns to service the 64K and 256K LCMs but
leaves the 4M LCMs in their current state.
This option is used to activate a new load in the STBY
bank following the successful completion of the
LOADPM command on an OOS unit.
Maintenance overview 1-21