Nortel DMS-100 Series Maintenance Manual page 353

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Testing power converter voltages
At your Current Location
1
Obtain a dc voltmeter.
2
Measure the voltage at the test points on the faceplates of both NT2X70 power
converters in the HIE shelf.
3
The voltages must be within 2% of the nominal values printed on the NT2X70
faceplate. Compare the voltages measured with the acceptable voltage ranges
given in the following table:
Test point voltage
+12 V
–12 V
+ 5 V
– 5 V
If test point voltages are
within acceptable range
not within acceptable range
4
Replace the NT2X70 power converter as Card Replacement
Procedures .directs.
When you return to this procedure, go to step 1.
5
This procedure is complete.
Routine maintenance procedures 11-7
Testing power converter voltages
Testing power converter voltages
Acceptable range
+11.76 V to +12.24 V
–12.24 V to –11.76 V
+4.9 V to +5.1 V
–5.1 V to –4.9 V
Do
step 5
step 4
DMS-100 Family Maintenance Manual ABSK007
HIE
HIE
(continued)
(end)

Advertisement

Table of Contents
loading

Table of Contents