Nortel DMS-100 Series Maintenance Manual page 223

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing a NT2X11 card in RMM
At your current location
1
Obtain a replacement card. Make sure that the replacement card has the same
product equipment code (PEC), including suffix, as the removed card.
At the MAP display
2
To access the TTP level of the MAP display and post the line test unit (LTU)
associated with the damaged card, type
>MAPCI;MTC;TRKS;TTP;POST T LTU ltu_no
and press the Enter key.
where
ltu_no
is the number of the line test unit that has faults
Example of a MAP response:
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
RMM 0 0
3
To busy the trunks associated with the damaged card, type
>BSY
and press the Enter key.
At the RMM shelf
4
Replace the NT2X11 card with the procedure "Replacing a card." When you
have completed the procedure, return to this point.
RLCM-EDC card replacement procedures 6-35
LTU
BUSY Q
COM LANG
LTU
21
DMS-100 Family Maintenance Manual ABSK007
NT2X11
in RMM
(continued)
DIG
STA S R DOT TE R
LO
P_IDL