Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Load sources for the RLCM-EDC
Parameter
Source
Bank
The following response is observed on the successful completion of a
LOADPM command when performed on an InSv or OOS unit.
>LOADPM UNIT 1 CC
Example of MAP response
LCM REM1 0 0 Unit 1 loadPM Passed.
When the source option used is SELFACT, the active bank of the unit being
loaded is the source for the load. The contents of the active bank are copied
into the STBY bank of the same unit.
>LOADPM UNIT 1 SELFACT
Example of MAP response
LCM REM1 0 0 Unit 1 loadPM Passed.
Value
Description
CC, MATE,
The SOURCE parameter is a required parameter.
SELFACT
Functionality of the command with a source value of CC
remains unchanged.
When the MATE option is used without specifying the
BANK parameter, the command defaults to STBY. This
means the STBY bank of the mate will be used as the
source for the load.
SELFACT is an acronym for SeLF ACTive. When the
source option is set to SELFACT, the active bank of the
unit being loaded is the source for the load. The
contents of the active bank are copied over to the
standby bank of the unit being loaded.
ACT, STBY
The BANK parameter is optional and is used only by
RLCM-EDC nodes. When used with the MATE option,
this parameter specifies the bank of the mate to use as
the source for the load.
This parameter is ignored by all other LCM variants
using the 64K/256K processors.
Maintenance overview 1-15
DMS-100 Family Maintenance Manual ABSK007